Set the trace level for PeSIT exchanges

To set the trace level for PeSIT:

  1. Go to <integration_engine_install_directory>/conf/ .
  2. Open the file log4j2.xml in a text editor.
  3. Edit the lines:
    • log4j.category.com.cyclonecommerce.tradingengine.transport.pesit=info – This line controls the level of detail of the interchange level trace (PeSIT monitor trace). If this entry exists, you can change its value. If it does not exist, you can add it. Accepted values are warning / info/ debug.
    • log4j.category.com.axway.transport.pesite=info – This line controls the level of detail of the PeSIT stack trace. If you set it to debug, you’ll see all PeSIT primitives and PIs as they are sent and received. It is very handy for troubleshooting. Accepted values are warning / info/ debug.
  4. Save and close the file.
Note   The debug trace level is quite verbose. To preserve performance, reserve this setting for troubleshooting.
Tip   Additional tracing:  To trace the frames as they are exchanged over the wire, the best method is to use a network sniffer.