Multi-datacenter failover scenarios

This topic describes expected behavior in a multi-datacenter deployment in case of failover. It explains how the system will behave in each of the following scenarios:

  • One API Gateway instance is down
  • One Apache Cassandra node is down
  • A full datacenter is down
  • The network between two datacenters is down

One API Gateway instance is down

In this case, one API Gateway instance is down in DC 1:

The following applies in this scenario:

  • API requests can no longer be serviced by the API Gateway instance that is not running in DC 1.
  • API requests will be serviced by the remaining API Gateway instance in DC 1.
  • You must restart the API Gateway instance that is not running in DC 1. For more details, see Start API Gateway.

One Cassandra node is down

In this case, one Cassandra node is down in DC 1:

The following applies in this scenario:

Note   When a node has been absent from a cluster for a time, it is brought back into the cluster after restart, and becomes eventually consistent by design. Node repair is required after re-integration into the cluster. For more details, see Perform essential Cassandra operations in the API Gateway Apache Cassandra Administrator Guide.

A full datacenter is down

In this case, DC 1 is down:

The following applies in this scenario:

  • API requests can no longer be serviced by DC 1
  • API requests are automatically directed to DC 2 by the load balancer
  • API Manager quotas remain the same but over less servers
  • You should not deploy updates for the following file-based data types to the API Gateway group:
    • API Gateway configuration
    • API Gateway KPS custom table structure
Note   There is a risk that end-users may need to re-initiate sessions using the following data types stored in Ehcache:
  • API Gateway OAuth token store
  • API Gateway custom cache

Restart the datacenter

To restart the datacenter:

  1. Restart each of the Cassandra nodes. For details, see Manage Apache Cassandra in the API Gateway Apache Cassandra Administrator Guide.
  2. When all Cassandra nodes are running normally and have synchronized with the rest of the cluster in DC2, you can restart the API Gateway instances. For details, see Start API Gateway. API Gateway should not be restarted prior to a successful restart of all Cassandra nodes.
Note   You should run the nodetool repair command on each of the three Cassandra nodes in DC 1 when the datacenter has been down for more than two hours.

The network between both datacenters is down

In this case, the network between DC 1 and DC 2 is down, while both datacenters remain active:

The following applies in this scenario:

  • OAuth or throttling data stored in Ehcache per datacenter is not affected
  • You should not deploy updates for the following file-based data types to the API Gateway group:
    • API Gateway configuration
    • API Gateway KPS custom table structure
  • For the following data types stored in Cassandra, both datacenters are not synchronized until the network recovers, and then automatically resynchronize:
    • API Manager catalog, client registry, web-based settings
    • API Gateway KPS custom table structure
  • For the following file based data types, a single API Gateway Manager web console cannot access both datacenters while the network is down, and can only access each datacenter separately:
    • API Gateway logs
    • API Gateway traffic monitoring
Note   If the network connection has been down for more than two hours, the following steps are recommended:

It may take a minute for newly created, deleted, or updated APIs in one datacenter to synchronize successfully with the other datacenter.

Further details

For more details on how to configure API Management in multiple datacenters, see: