Monitor hardware using Dell OpenManage

Dell OpenManage Server Administrator (OMSA) is a system management solution that can be accessed through either an integrated web interface or a command-line interface (CLI). This topic describes some of the omreport commands that you can use to display reports of the management information of the system. For more information on the OMSA command-line interface, see the Dell OpenManage Server Administrator Command Line Interface Guide, available from the Dell Support website.

omreport

The omreport command reports on a particular system subsection. The subsections can be listed with a -? supplied to the command. For example:

# omreport -?       

omreport         Reports component properties.

The available command(s) are:

Command          Description
about            Product and version properties.
system           System component properties.
rac              Command not supported. Use the racadm utility.
chassis          Chassis component properties.
storage          Display storage component properties.

omreport chassis

This command gives a report of the overall hardware in the server. For example:

# omreport chassis    
Health

Main System Chassis

SEVERITY : COMPONENT
Ok       : Fans
Ok       : Intrusion
Ok       : Memory
Ok       : Power Supplies
Ok       : Power Management
Ok       : Processors
Ok       : Temperatures
Ok       : Voltages
Ok       : Hardware Log
Ok       : Batteries

omreport chassis bmc

To see iDRAC/IPMI settings specify bmc (Baseboard Management Controller) to the command. For example:

# omreport chassis bmc
Remote Access Information

Remote Access Device
Attribute : Device Type
Value     : iDRAC6 Express

Attribute : IPMI Version
Value     : 2.0

Attribute : System GUID
Value     : 2020204f-c080-2080-2010-00004c4c4544

Attribute : Number of Possible Active Sessions
Value     : 5

Attribute : Number of Current Active Sessions
Value     : 0

Attribute : Enable IPMI Over LAN
Value     : Yes

Attribute : SOL Enabled
Value     : Yes

Attribute : MAC Address
Value     : 14-FE-B5-D1-57-3B


IPv4 Address
Attribute : IP Address Source
Value     : DHCP

Attribute : IP Address
Value     : 192.168.0.152

Attribute : IP Subnet
Value     : 255.255.255.0

Attribute : IP Gateway
Value     : 192.168.0.3

omreport chassis batteries

This command reports on the batteries. For example:

# omreport chassis batteries
Batteries

Health : Ok

Individual Battery Elements
Index      : 0
Status     : Ok
Probe Name : System Board CMOS Battery
Reading    : Good

omreport storage

The omreport storage command allows you to view reports for the storage system on the server.

omreport storage vdisk

This command reports on the virtual disks. For example:

# omreport storage vdisk  
List of Virtual Disks in the System

Controller PERC 6/i Integrated (Embedded)
ID                  : 0
Status              : Ok
Name                : Virtual Disk 0
State               : Ready
Progress            : Not Applicable
Layout              : RAID-1
Size                : 136.13 GB (146163105792 bytes)
Device Name         : /dev/sda
Bus Protocol        : SAS
Media               : HDD
Read Policy         : No Read Ahead
Write Policy        : Write Back
Cache Policy        : Not Applicable
Stripe Element Size : 64 KB
Disk Cache Policy   : Disabled

omreport storage battery

This command reports on the batteries. For example:

# omreport storage battery
List of Batteries in the System

Controller PERC 6/i Integrated (Slot Embedded)
ID                        : 0
Status                    : Ok
Name                      : Battery 0
State                     : Ready
Recharge Count            : Not Applicable
Max Recharge Count        : Not Applicable
Predicted Capacity Status : Ready
Learn State               : Idle
Next Learn Time           : 41 days 6 hours
Maximum Learn Delay       : 7 days 0 hours
Learn Mode                : Auto

omreport system

The omreport system command allows you to see a general status of the components of the system.

omreport system summary

Use the omreport system summary command to view a comprehensive summary of software and hardware components currently installed on the system. For example:

# omreport system summary
System Summary

------------------
Software Profile
------------------
Systems Management
Name                       : Information not available.
Version                    : 3.6.0
Description                : Systems Management Software

Operating System
Name                       : Linux
Version                    : Kernel 2.6.32.200(x86_64)
System Time                : Wed Oct 26 17:05:08 2011
System Bootup Time         : Wed Oct 26 16:39:00 2011

--------
System
--------
System
Host Name                  : appliance
System Location            : Please set the value
Life Cycle Controller      : Enabled

---------------------
Main System Chassis
---------------------
Chassis Information
Chassis Model              : PowerEdge R610
System Revision            : II
Chassis Service Tag        :
Chassis Lock               : Present
Chassis Asset Tag          : FZBHY4J

Remote Access Information
Remote Access Device       : iDRAC6 Express

Processor 1
Processor Brand            : Intel(R) Xeon(R) CPU           E5620  @ 2.40GHz
Processor Version          : Model 44 Stepping 2
Voltage                    : 1200 mV

Processor 2
Processor Brand            : Intel(R) Xeon(R) CPU           E5620  @ 2.40GHz
Processor Version          : Model 44 Stepping 2
Voltage                    : 1200 mV

Memory
Total Installed Capacity   : 6144  MB
Memory Available to the OS : 3276  MB
Total Maximum Capacity     : 196608  MB
Memory Array Count         : 1

Memory Array 1
Location                   : System Board or Motherboard
Use                        : System Memory
Installed Capacity         : 6144  MB
Maximum Capacity           : 196608  MB
Slots Available            : 12
Slots Used                 : 6
ECC Type                   : Multibit ECC

Slot PCI1
Adapter                    : [Not Occupied]
Type                       : PCI E Gen 2
Data Bus Width             : 8x or x8
Speed                      : [Not Obtained, see card documentation]
Slot Length                : Long
Voltage Supply             : 3.3 Volts

Slot PCI2
Adapter                    : Nitrox XL NPX
Type                       : PCI E Gen 2
Data Bus Width             : 8x or x8
Speed                      : [Not Obtained, see card documentation]
Slot Length                : Long
Voltage Supply             : 3.3 Volts

BIOS Information
Manufacturer               : Dell Inc.
Version                    : 3.0.0
Release Date               : 01/31/2011

Firmware Information
Name                       : iDRAC6
Version                    : 1.57

--------------
Network Data
--------------
Network Interface 0
IP Address                 : 192.168.0.158
Subnet Mask                : 255.255.255.0
Default Gateway            : 192.168.0.3
MAC Address                : 14:FE:B5:D1:57:33

Network Interface 1
IP Address                 : [No Value]
MAC Address                : 14:FE:B5:D1:57:35

Network Interface 2
IP Address                 : [No Value]
MAC Address                : 14:FE:B5:D1:57:37

Network Interface 3
IP Address                 : [No Value]
MAC Address                : 14:FE:B5:D1:57:39

--------------------
Storage Enclosures
--------------------
Storage Enclosures
Name                       : Backplane
Service Tag                : 09K3440

Related Links